My LCHCS web interface works fine, I have it connected to my 2.4GHz wifi (not the 5Ghz wifi). I can see the serial number, limited charging stats, and even use the ping tool. What I CANNOT do, though, is download the logs. I'm using the devtools in the browser and it appears that when you first go to the maintenance page, it asynchronously requests 'compresslog.cgi'. Based on the underlying javascript code, this function should return the filename of the compressed log. Unfortunately, the HTTP request times out after 60 secs (a timeout value in the web server on the charger...I've tried it with CURL after spoofing the session cookie and other headers with a 3 minute timeout for the client and it still fails after 60 secs).
It appears there is 1) an ENGINEERING mode (requires engineering password) which might be of use, and 2) You can ssh to the charger (it's running sshd on port 22), but I don't have any credentials to login.
I've REBOOTED the charger and the logs still timeout. I've even FACTORY RESET (requiring me to reconfigure the whole charger to reconnect to my SSID) with no luck....the 'total energy delivered' stat is still there, which means it's not fully erasing all the data.
Any ideas for how to pull the logs which are apparently now so bloated, they can't be gzipped or zipped inside of 60 secs? Or, anyone know the Engineering passwd or SSH credentials?
It appears there is 1) an ENGINEERING mode (requires engineering password) which might be of use, and 2) You can ssh to the charger (it's running sshd on port 22), but I don't have any credentials to login.
I've REBOOTED the charger and the logs still timeout. I've even FACTORY RESET (requiring me to reconfigure the whole charger to reconnect to my SSID) with no luck....the 'total energy delivered' stat is still there, which means it's not fully erasing all the data.
Any ideas for how to pull the logs which are apparently now so bloated, they can't be gzipped or zipped inside of 60 secs? Or, anyone know the Engineering passwd or SSH credentials?